I Training Council, Version correct as of 06/08/2009 01 :37, (c) DDIEC/PAS 61076-2-108:2009 PAS61076-2-108@IEC:2009(E) - 13 - Table 2 - Connectors dimensions in mated and locked position d1 h a" max I a) max Figure Combination of styles xew e xewp WM-JF 021 14,2 n/a 69 WM-LF 016 14,2 n/a 52 XM-JF 021 18 - n/a 67,5 XM-LF - 016 18 n/a 50,5 5 a) YM-JF 021 14 n/a 72,5 YM-LF 016 14 n/a 55,5 ZM-JF 021 19 n/a 71,5 ZM-LF -- 016 19 n/a 54,5 WM-KF 11 021 14,2 64 43,5 WM-MF 8 016 14,2 36,5 39 XM-KF 11 021 18 62,5 43,5 8 016 18 35 39 XM-MF 5 b) YM-KF 11 021 14 67,5 43,5 YM-MF 8 016 14 40 39 ZM-KF 11 021 19 66,5 43,5 ZM-MF 8 016 19 39 39 All dimensions are in mm. B See Figure 5. Licensed copy: Vocational Trading Council, Vocational a) Dimensions in mated and locked position, additional space for insertion: 15 mm. t as of 06/08/2009 01:37, DD IEC/PAS 61076-2-108:2009 PAS 61076-2-108 @ IEC:2009(E) -14 - 4 Characteristics 4.1 Climatic category The climatic category characteristics shall be in accordance with 4.1 of IEC 61076-2-101. 4.2 Electrical The electrical characteristics shall be in accordance with 4.2 of IEC 61076-2-101. , Version correct 4.3 Mechanical 4.3.1 IP degree of protection The IP degree of protection shall be in accordance with 4.3.1 of IEC 61076-2-101. 4.3.2 Mechanical operation Council, The mechanical operation shall be in accordance with 4.3.2 of IEC 61076-2-101. 4.3.3 Insertion and withdrawal forces The mechanical operation shall be in accordance with 4.3.3 of IEC 61076-2-101. Training 4.3.4 Contact retention in insert S Not applicable, see also 4.3.4 of IEC 61076-2-101 B , Vocational 4.3.5 Polarizing method The polarizing method shall be in accordance with 4.3.5 of IEC 61076-2-101. 4.3.6 Vibration (sinusoidal) The vibration (sinusoidal) shall be in accordance with 4.3.6 of IEC 61076-2-101. 4.3.7 Pressure differential IEC 60512 Test 14b Conditions: Standard atmospheric conditions Connectors unmated Lubricant notrequired Pressure differential 100 ± 5 kPa No leakage permitted Licensed copy: Vocational T 3/2009 01:37, DDIEC/PAS 61076-2-108:2009 PAS 61076-2-108 @ IEC:2009(E) - 15 - Test schedule t as of 06/08/ 5.1 General The test schedule shall be in accordance with 5.1 of IEC 61076-2-101. 5.2 Test schedule 5.2.1 Test group P - Preliminary , Version correct The test group P-Preliminary shall be in accordance with 5.2.1 of IEC 61076-2-101 except for the addition of test phase P6 as below: Table 3 - Test group P Measurement to be Test Requirements performed Test phase IEC IEC Severity or Council, Title 60512 Title 60512 All connector styles condition of test Test No. Test No. P6 Differential 14b As 4.3.7 There shall be no leakage pressure at ambient temperature The specimens shall be divided into five groups. All connectors in each group shall undergo Training the tests specified for the relevant group. S 5.2.2 Test group AP - Dynamic/ Climatic B The test group AP - Dynamic/ Climatic shall be in accordance with 5.2.2 of IEC 61076-2-101 Vocational except for the addition of the pressure differential test into Test phase AP7.3 as below: Table 4 - Test group AP Measurement Test Requirements to be performed Test IEC IEC phase Severity or Title 60512 Title 60512 condition of test Test No. Test No. AP7.3 Contact 2 Rise in relation to initial resistance values 15 m2 max. Millivolt 2b level Insulation 3a 10° 2 min. resistance Voltage 4a According to 4.2.2 proof copy: Vocational Insertion 13b See 4.3.3 and withdrawal forces Pressure 14b Requirements as 4.3.7 differential Licensed
IEC PAS 61076-2-108 2009 Connectors for electronic equipment - Product requirements - Part 2-108 Circular connectors - Detail specification for glass to metal seal style M12 connectors with screw-lock
文档预览
中文文档
8 页
50 下载
1000 浏览
0 评论
309 收藏
3.0分
温馨提示:本文档共8页,可预览 3 页,如浏览全部内容或当前文档出现乱码,可开通会员下载原始文档
本文档由 人生无常 于 2025-03-28 01:20:35上传分享